We are a NLCAA Acceptance Test Employer: ATE-1703-00003
Our Title 24 Inspectors are Certified Acceptance Test Technicians, ensuring the high quality installation of energy efficiency lighting controls systems and title 24 certification.
We service all of California.
Shut-Off Lighting Control Acceptance (NRCA-LTI-02-A) The most common Title 24 acceptance test is comprised of testing the auto shutoff function of a lighting control system. To comply with the requirements in this test; all of the main area lighting, (except emergency lighting) must automatically shut off, when the space is empty. Therefore; an occupancy sensing device must be installed, to control the lighting in all rooms / spaces.
Shut-Off Lighting Control Acceptance Forms: 2019-NRCA-LTI-02-A
Automatic Daylighting Control Acceptance (NRCA-LTI-03-A) The second most common Title 24 acceptance test is the NRCA-LTI-03-A acceptance test. This is the test for compliance of automatic daylighting systems. Daylighting is required in new construction projects; with >120W in the primary daylight zones, and tenant improvements with >80% of the allowable w/sq. ft. For compliance; a system that automatically reduces electric lighting when daylight is present, must be installed and calibrated to the appropriate Title 24 Code requirements.
Automatic Daylighting Control Acceptance Forms: 2019 NRCA-LTI-03-A
Demand Responsive Lighting Control Acceptance (NRCA-LTI-04-A) Verify the demand responsive control is capable of receiving a demand response signal directly or indirectly through another device and that it complies with the requirements of the California Energy Efficiency Standards.
Demand Responsive Lighting Control Acceptance Forms: 2019-NRCA-LTI-04-A
Institutional Tuning Outdoor Lighting (NRCA-LTI-05-A)
Institutional Tuning Outdoor Lighting Forms: 2019-NRCA-LTI-05-A
Outdoor Lighting Acceptance Tests (NRCA-LTO-02-A)
Outdoor Lighting Acceptance Test Forms: 2019-NRCA-LT0-02-A
NRCI-LTI-01-E This form lists all of the necessary documents for describing your project's Title 24 compliance. If you need assistance, filling out your NRCI-LTI-01-E documents please contact ELP, LLC.
NRCI-LTI-02-E This form lists all installed devices and equipment are in compliance with Title 24.
If you need assistance, filling out your NRCI-LTI-02-E documents please contact ELP, LLC.
2019 Building Energy Efficiency Standards (effective January 1, 2020) requirements
We review your project's construction documents, confirming all installed lighting controls are Title 24 compliant, then an on-site Title 24 Inspection and functional tests is performed, ensuring the lighting control systems operate properly. Upon a passing grade; Title 24 Acceptance Certificates are issued.
Our goal is to assist engineering firms, lighting designers and electrical contractors, to stay on schedule for final electrical inspection, Title 24 Inspection and quickly receiving Certificate of Occupancy and their Title 24 Acceptance Certification.
Title 24 Acceptance Testing, on Time, the First Time.
Depending on the size of the project, (barring any corrections and a re - inspection) ELP, LLC's Title 24 Inspector will deliver the Title 24 report within one business day of the site inspection.
Serving all of California.
ELP - Electrical Lighting Professionals, LLC performs Title 24 Acceptance Testing and Title 24 Acceptance Certification.
Serving all of California.
License #: 1023909
ATE-1703-00003
If you have any questions regarding your location, please call ELP, LLC prior to completing your purchase.
ELP, LLC ACCEPTS MAJOR CREDIT CARDS.
Copyright © 2021 ELP - Electrical Lighting Professionals, LLC - All Rights Reserved.
Lic. # 1023909
Mon - Fri: 5am-9pm - Weekends: By Appointment
Our website uses cookies. By continuing to use this site, you accept our use of cookies.